IGSMHS4G Installation and Setup Guide
PROMPTS
Comm Path
9
Choice
(IP&GSM)_
Device Mode
10
(ECP)_
Important Information Regarding Primary Account (Prompts 11-13)
Account information is provided by the central station administrator.
Primary City ID
11
(??)_
Primary CS ID
12
(??)
Primary Sub ID
13
(????)
Device Address
14
(12)_
Direct Wire
Y/N
15
(N)_
Keypad Address
16
(28)_
3-12
4204/
ZONE
OPTIONS
TRIG.
2-4204
• IP&GSM
4
4
• IP
• GSM
• ECP
4
4
• Zone Trig.
• 4204 Emu
• Two 4204s
[01-99]
4
4
[01-FE]
4
4
[0001-9999]
4
4
[01-15]
4
[Y], [N]
4
[01-30]
4
DESCRIPTION
Press the [space] key to scroll through the communica-
tion path choices. Press [ENTER] to select.
For maximum reliability, select IP&GSM, and ensure
the Internet is connected using the Ethernet cable.
NOTE: After going from a "GSM" only com path choice
to an "IP" only choice, Prompt 68: "DHCP" will default to
No.
Press the [space] key to scroll through the modes of
operation.
Press [ENTER] to select mode.
IMPORTANT, if ECP device mode is desired, use
Table 3-2 for programming.
Enter the 2-digit primary city ID, 01-99 (decimal).
Enter the 2-digit primary central station ID number, 01-
FE (HEX).
Enter the 4-digit subscriber account number, 0001-9999
(decimal).
The IGSMHS4G communicates with the control panel as
a 4204 relay module. Enter the appropriate address.
For VISTA-10P, and FA130CP Series control panels,
this must be address 12. For other control panels, see
their Installation and Setup Guide.
NOTES:
1. The 4204 protocol limits address range to 01-15. If
using 2-4204 mode, the communicator assigns the
second 4204 to the next higher device address (e.g., if
entering address 12 for the first 4204, then address
13 is automatically assigned to the second 4204
module). Program the control panel accordingly.
2. The device address(es) must be unique from the
"Keypad Address" entered in Prompt 16 and any
other address used on the control panel.
Enables Direct Wire Downloading over IP. This applies
only to the Vista-32FB and VISTA BP and FBP series
control panels with revision 3.x. BP and FBP panels rev
4.x and higher support Downloading via IP over ECP. If
[N], skip to Prompt 17: "Supervision."
Must be programmed if using Direct Wire downloading.
Enter the appropriate device address.
NOTES:
1. This address must also be programmed as an alpha
keypad in the control panel or an AUI (Advanced User
Interface) type device, if a full enhanced graphic
interface to the system is desired and the control panel
supports it. DO NOT connect an actual keypad (or any
other device) assigned to this address.
2. This address must be unique from the "Device
Address" entered in Prompt 14, and cannot equal that
device address plus 1 (one) if using 2-4204 mode.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Igsmhs4g

Table of Contents