PROMPTS
Tamper Rpt Y/N
30
(Y)_
ECP mode supports two optional hardwire zone input triggers by making connections to the communicator's zone 6
and/or zone 7 terminals and programming the appropriate zone trigger options below.
Each zone input can be programmed to cause an alarm under one of the following conditions:
• (V+), where a positive voltage causes an alarm for normally low connections (voltage trigger, NO, NC)
• (V–), where a ground trigger causes an alarm for normally high connections (open collector, NO, NC)
• (EOLR) End of Line Resistor, where the input is supervised by a 2K EOL resistor. The zone can be triggered
by open collector, voltage trigger, NO, NC.
UL: Set V+ to inverted, and V– as non-inverted.
In addition to the above, zones can be programmed for an Inverted Trigger, where the alarm and normal states of
the zones are inverted; this can serve a fail-safe supervisory purpose for certain installations.
These zone inputs can also be programmed for restore reporting, and for delayed reporting (NOT for UL installa-
tions), which allows time for the user to abort false alarms.
NOTE: Optional hardwire zones report in ADEMCO High-Speed format.
Enable Zn6 Y/N
31
(N)_
Zn6 Trigger Type
32
(V+)_
Invert Zn6 Y/N
33
(N)_
Restore Zn6 Y/N
34
(Y)_
Delay Zn6 (secs)
35
(00)_
Enable Zn7 Y/N
36
(N)_
Zn7 Trigger Type
37
(V+)_
Invert Zn7 Y/N
38
(N)_
Restore Zn7 Y/N
39
(Y)_
Delay Zn7 (secs)
40
(00)_
OPTIONS
[Y], [N]
Sends a tamper report when the communicator detects a tamper
condition. A tamper restore is automatically sent when the tamper
condition clears.
UL: Must be set to "Y."
Important Information Regarding Zone Input Options
[Y], [N]
Enables alarm reporting for zone 6.
If [N], skip to Prompt 36: "Enable Zn7."
• (V+)
Selects the triggering method for this zone input.
• (V–)
Press the [space] key to scroll through choices.
• (EOLR)
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Inverts the alarm and normal states of the zone 6 trigger; otherwise
uses normal input signal.
Enables restore reporting for zone 6.
[Y], [N]
[01-15]
Defines the reporting delay in seconds for zone 6.
UL: Must be set to 00.
[00] = no delay
[Y], [N]
Enables alarm reporting for zone 7.
If [N], skip to Prompt 41: "Use DHCP."
• (V+)
Selects the triggering method for this zone input.
• (V–)
Press the [space] key to scroll choices.
• (EOLR)
UL: V+ must be set as inverted and V– as
non-inverted.
Inverts the alarm and normal states of the zone 7 trigger; otherwise,
[Y], [N]
uses normal input signal.
[Y], [N]
Enables restore reporting for zone 7.
[01-15]
Defines the reporting delay in seconds for zone 7.
[00] = no delay
UL: Must be set to 00.
Section 3: Programming the Communicator
DESCRIPTION
3-7