PROMPTS
Restore and Delayed Reports: Zone inputs can be programmed for restore reporting, and for delayed reporting
(NOT for UL installations) which allows time for the user to abort false alarms.
UL: Zone restoral must be enabled.
Report Only if Armed option: To help eliminate redundant reports, zone alarms can be restricted to report only if
a conditional zone is triggered (armed). If this feature is desired, the conditional zone is automatically used as the
"arming" zone. Connect the appropriate control panel trigger to the conditional (arming) zone. The trigger must be
programmed as necessary in the control panel.
The conditional (arming) zone on the communicator is a different dedicated zone for each programming mode, as
follows:
IMPORTANT: If any zone (zones 1-6 in zone trigger mode, zones 1-3 in 4204 mode, zones 1-7 in 2-4204 mode) is set
for Report Only if Armed, the conditional (arming) zone becomes unavailable for reporting (as it is reserved for the
"arming" trigger connection).
Trip Inputs 1or2
28
w/Bell Out (N)_
Telco Zone
29
(0)_
Open/Close Zone
30
(0)_
4204/
ZONE
OPTIONS
TRIG.
2-4204
Mode
Zone Trigger
4204
2-4204
[Y], [N]
4
Zone Trig:
4
4
[3-7]
4204: [1-4]
2-4204:
[1-8]
[0] = not
used
Zone Trig:
4
4
[3-7]
4204: [1-4]
2-4204:
[1-8]
[0] = not
used
Section 3: Programming the Communicator
Conditional (Arming) Zone
7
4
8
Use if the zone 1 connection to the control panel's bell
output causes a bell fault on the control panel.
NOTES:
1. If used, EOLR trigger type is not available for zones 1
and 3.
2. Do not use with Lynx controls.
See Important Information above, Regarding Zone Input
Options.
Enter the zone number to be used for Telco line fault
reports. This zone assignment must be unique from the
open/close zone selected in Prompt 30.
Zone Trigger Mode: If any zone is programmed for
"report only if armed," zone 7 cannot be used. If
Lynx Panic is enabled, zone 3 cannot be used.
4204 Mode: If any zone is programmed for "report only
if armed," zone 4 cannot be used.
2-4204 Mode: If any zone is programmed for "report
only if armed," or if tamper is enabled, zone 8 cannot
be used.
NOTE: Connect the Telco line fault output (or relay
output programmed for "Telco line fault") to the Telco
zone.
Enter the zone number to be used for open/close
(arm/disarm) reports.
This zone assignment must be unique from the Telco
zone selected in Prompt 29.
Zone Trigger Mode: If any zone is programmed for
"report only if armed," zone 7 cannot be used as an
open/close zone. If Lynx Panic is enabled, zone 3
cannot be used.
4204 Mode: If any zone is programmed for "report only
if armed," zone 4 cannot be used as an open/close
zone.
2-4204 Mode: If any zone is programmed for "report
only if armed," or if tamper is enabled, zone 8 cannot
be used as an open/close zone.
NOTE: Connect an open/close (arm/disarm) trigger (or
relay output) from the control panel to the open/close
zone.
DESCRIPTION
3-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Igsmhs4g

Table of Contents