Canon Super G3 Fax Board-J1 Service Manual page 57

Revision 0
Table of Contents

Advertisement

#1 SSSW-SW12: page timer setting
Bit
Function
0
Time-out period for one page upon 1
transmission
1
2
Time-out period for one page upon 1
transmission (HT transmission)
3
4
Time-out period for one page upon 1
reception
5
6
not used
7
Respective page timer settings for enable
transmission and for reception
The machine will stop the ongoing communication if the transmission/reception of a
single original page takes 32 min or more. To use the timer for a purpose other than this
function, refer to the tables that follow, and select an appropriate time length.
When 'disable' is selected using bit 7, the time-out length for a single page for all modes
will depend on the setting of bit 0 and bit 1.
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CHAPTER 5 SERVICE MODE
1
0
0
1
0
0
1
0
0
1
0
do not enable
CANON SUPER G3FAX BOARD-J1 REV.0 JUNE 2001
Factory setting
0
1
0
0
0
0
0
0
5-15

Advertisement