Position Of Docking Target Co-Ordinates - Renishaw SP600 Installation And User Manual

Scanning probe system
Table of Contents

Advertisement

SP600 installation and user's guide
www.renishaw.com
Step 4 - Establishing docking centre for ports 2 to 4
Using the centre of port 1 as a reference, add 53.5 mm (2.11 in) to establish the docking centre for port 2 (Y2)
Using the centre of port 2 as a reference, add 53.5 mm (2.11 in) to establish the docking centre for port 3 (Y3)
Using the centre of port 3 as a reference, add 53.5 mm (2.11 in) to establish the docking centre for port 4 (Y4)

Position of docking target co-ordinates

Port 1 = X, Y1, Z
Port 2 = X, Y2, Z
Port 3 = X, Y3, Z
Port 4 = X, Y4, Z
Issued 01 2018