Figure 3-30: Mounting in concrete silos
Remote mount
3.2.10.1
In applications where a remotely mounted display is required, the remote mount allows
the electronics housing to be mounted 3m away from the process connector. This can be
useful when access to the mounting location is limited. To assemble the remote mount,
attach the process connector first, followed by securing the mounting bracket to a pipe or
wall. Secure the electronics module to the bracket with the 3 supplied M6 screws.
Connect the cable and check bends for minimum radius (see
Figure
3-31) to prevent
damage. Torque the 2 nuts to 6Nm (4.4ft-lbs).
SLG 700 SmartLine Level Transmitter User's Manual
Revision 7