4.3.1 Correlation Model Recalculation

Information on what triggers a correlation model recalculation is summarized in the table
below.
Parameter recalculated
Surface Model Gain
Interface Model Gain
End of Probe Model Gain, Width, Attenuation
Process Connector Model Gain, Width,
Attenuation
Propagation Factor
Vapor Attenuation
Minimum BDH/BDL
BDH/BDL
Page 88

Table 4-4: Correlation Model Recalculation

SLG 700 SmartLine Level Transmitter User's Manual
Parameters that will trigger
recalculation / reset required
Vapor DC, Upper DC, Lower DC, Application
Type, Probe Type, Transmitter Model,
Mounting Location, Sensor Connection Type,
Mounting Diameter
Upper DC, Lower DC, Application Type,
Probe Type, Transmitter Model, Mounting
Location, Sensor Connection Type, Mounting
Diameter
Probe Type, Probe End Type, Centering Disc
Diameter, Transmitter Model, Mounting
Location, Sensor Connection Type, Mounting
Diameter
Transmitter Model, Sensor Connection Type,
Probe Type
Transmitter Model, Probe Type
Transmitter Model, Probe Type
Vapor DC, Upper DC, Lower DC, Probe
Type, Application Type
Vapor DC, Upper DC, Lower DC, Probe
Type, Application Type