Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Honeywell Manuals
Radar
SmartLine SLG 700
User manual
Table 3-3: Sensor Details - All Models; Table 3-4: Minimum Blocking Distances And Transition Zones For The Various Probe Types; Table 3-5: Maximum Measurement Range For Each Probe Type Versus Dielectric Constant - Honeywell SLG 700 User Manual
Smartline level transmitter guided wave radar
Hide thumbs
Also See for SLG 700
:
Option manual
(220 pages)
,
User manual
(198 pages)
,
Quick start manual
(40 pages)
1
2
3
4
5
6
Table Of Contents
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
page
of
176
Go
/
176
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Parameter
Probe
*Only for model SLG720
Table 3-4: Minimum blocking distances and transition zones for the various probe
Probe
Type
Water
Rod/Wire
(DC=80)
Rod/Wire
Oil (DC=2)
Water
Coax
(DC=80)
Coax
Oil (DC=2)
Table 3-5: Maximum measurement range for each probe type versus dielectric
Min DC
1.4
Probe
1.8
3
4
6
Revision 7
Table 3-3: Sensor Details – All Models
Description
Type
Rod
0.4m (1.3ft) / 6.3m (20.7ft)
Wire
1.0m (3.3ft) / 50m (164 ft)
Coax
0.4m (1.3ft) / 6.3m (20.7ft)
Minimum
Media in
Blocking
Tank
Distance
High [cm]
9
7
5
5
Wire
Range
Min DC
15m (49ft)
1.4
25m (82ft)
42m (138ft)
46m (151ft)
50m (164ft)
SLG 700 SmartLine Level Transmitter User's Manual
Min / Max Length
types
Upper
Transition
Zone, T
up
[cm]
13
14
14
8
constant.
Rod
Range
6.3m (21ft)
Materials
SS 3161L, C-276*
SS 316
SS 3161L, C-276*
Minimum
Lower
Blocking
Transition
Distance
Zone, T
Low [cm]
[cm]
0
1
0
12
2
0
6
7
Coax
Min DC
Range
1.4
6.3m (21ft)
Page 31
low
Table of
Contents
Previous
Page
Next
Page
1
...
40
41
42
43
44
45
46
47
Advertisement
Table of Contents
Related Manuals for Honeywell SLG 700
Measuring Instruments Honeywell SLG 700 Option Manual
Smartline level transmitter guided wave radar foundation fieldbus (220 pages)
Transmitter Honeywell SmartLine SLG 700 User Manual
Level transmitter guided wave radar (198 pages)
Measuring Instruments Honeywell SLG 700 User Manual
Smartline level transmitter guided wave radar hart option (132 pages)
Radar Honeywell SLG 700 Quick Start Manual
Smartline level guided wave radar (40 pages)
Radar Honeywell PRIMUS 660 Pilot's Manual
Primus digital weather radar system (162 pages)
Radar Honeywell BENDIX/KING RDR 2000 Installation Manual
Color weather radar system (128 pages)
Radar Honeywell IntuVue RDR-4000 Pilot's Manual
3-d automatic weather radar system with forward looking windshear detection (68 pages)
Radar Honeywell Primus 880 Pilot's Manual
Digital weather radar system (161 pages)
Radar Honeywell IntuVue RDR-7000 Pilot's Manual
3-d automatic weather radar system for fixed wing aircraft (68 pages)
Radar Honeywell Enraf SmartRadar FlexLine Installation Manual
(52 pages)
Radar Honeywell SMARTLINE RM77 Supplementary Instructions Manual
10 ghz radar (fmcw) level meter for distance, level, volume, flow, mass and reflection measurement of liquids (42 pages)
Related Content for Honeywell SLG 700
Primus 880 Dual Control Mode Truth Table
Honeywell Primus 880
PRIMUS 660 Table Of Contents (Cont)
Honeywell PRIMUS 660
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL