Allen-Bradley SafeZone Mini User Manual page 47

Safety laser scanner
Table of Contents

Advertisement

Figure 19 - Minimum Distance to the Hazardous Area
Contour as
reference
The minimum distance S as defined in EN ISO 13855 and EN ISO 13857
depends on the following:
• Stopping/run-down time of the machine or system
(The stopping/run-down time is shown in the machine documentation
or must be determined by taking a measurement.)
• Response time of the SafeZone Mini device
• Reach or approach speed
• Resolution of the SafeZone Mini device
Calculate Minimum Distance S
See EN ISO 13855. Calculate S with the following formula:
S = 2000 × (T
+ T
) + 8 × (d - 14) [mm]
M
S
Variable Description
T
Stopping/run-down time of the machine or system
M
T
Response time of the SafeZone Mini device
S
d
Resolution of the SafeZone Mini device [mm]
The reach/approach speed is already included in the formula.
• If the result S is ≤ 500 mm (19.7 in.), then use the determined value as
the minimum distance.
• If the result S is > 500 mm (19.7 in.), you may be able to reduce the
minimum distance with the following calculation:
S = 1600 × (TM + TS) + 8 × (d – 14) [mm]
• If the new value S is > 500 mm (19.7 in.), then use the newly calculated
value as the minimum distance.
• If the new value S is ≤ 500 mm (19.7 in.), then use 500 mm (19.7 in.) as
the minimum distance.
Rockwell Automation Publication 442L-UM005B-EN-P - April 2017
Mounting
S
Chapter 4
47