Mounting
Chapter 4
Using Multiple Safety Laser Scanners
The SafeZone Mini device is designed so that mutual interference between
several safety laser scanners is unlikely. To exclude erroneous switching, you
must mount the safety laser scanners as shown in the following examples.
IMPORTANT In any circumstance, observe EN ISO 13855 when calculating the minimum
distance.
Use mounting kits 1 or 2 and 3 to adjust the safety laser scanners to different
angles (see
Table 25 on page
95).
Figure 33 - Opposite Mounting
Min. 3°
Figure 34 - Offset Parallel Mounting
Min. 100 mm
(3.94 in.)
Figure 35 - Mounting on a Cross
Min. 3°
Figure 36 - Reverse Mounting, Parallel Offset
Min. 100 mm
(3.94 in.)
Figure 37 - Reverse Mounting of Two SafeZone Mini Devices, with Parallel Offset
Min. 100 mm
(3.94 in.)
59
Rockwell Automation Publication 442L-UM005B-EN-P - April 2017