Recommission The Safezone Mini Device - Allen-Bradley SafeZone Mini User Manual

Safety laser scanner
Table of Contents

Advertisement

Figure 47 - Optics Cover Mounting Screws
Screw
5. Remove the optics cover.
6. Check whether the mirror on the motor is clean and remove any
contamination with an optic brush.
7. Take the new optics cover out of the packaging and remove the
protection for the seal.
8. Remove any remnants of packaging.
9. Place the optics cover on the safety laser scanner and place the new
mounting screws.
IMPORTANT When fitting the new cover, verify that the arrow on the top of the cover
points to the front and that the optics cover is fully in contact without a gap.
10. Tighten the front screws with the torque wrench.
11. Make sure that the optics cover is free of dirt and that it is not damaged.

Recommission the SafeZone Mini Device

1. Correctly remount the SafeZone Mini device (see
page
39).
2. Connect the round plug connector on the end of the connection cable
for the SafeZone Mini device.
3. Perform an optics cover calibration with the aid of the SCD software.
Rockwell Automation Publication 442L-UM005B-EN-P - April 2017