With two SafeZone Mini devices mounted at an angle of 45° on the front
corners of a vehicle, you can configure the protective fields so that there are no
unprotected areas and the hazardous areas in narrow aisles can also be
protected.
Figure 27 - Mounting Example for Front and Side Protection in a Direction of Travel
Protective field and
warning field safety
laser scanner 1
With two SafeZone Mini devices mounted diagonally opposite, you can
implement protective fields on the vehicle for all-round protection in all
directions of travel.
Figure 28 - Mounting Example for All-around Protection in All Directions of Travel
Protective field and
warning field safety
laser scanner 1

Near Range

Make the near range impassible using a bar or a recess, or additionally protect
the near range (50 mm (2.0 in.)) wide area in front of the optics cover using a
proximity switch with 50 mm (2.0 in.) acquisition range. The vehicle can then
be accelerated as required.