Error And Status Indication - Status Indicators - Allen-Bradley SafeZone Mini User Manual

Safety laser scanner
Table of Contents

Advertisement

Chapter 10
Diagnostics
Error and Status
Indication —
Status Indicators
80
This section describes the meaning of the error and status indications of the
status indicators and how you can respond. You can find a description of the
indicators in
Status Indicators on page
the SafeZone™ Mini device in
Table 14 - Error and Status Indication
Display
Output Level
At the OSSDs
At the OSSDs
At the warning field
output
On the universal I/O
At the OSSDs
On the universal I/Os
On the universal I/O
No level change
On the universal I/O
On the universal I/O
On the universal I/O
(1) If warning field 1 is infringed.
(2) If this is configured as the output for warning field 2 and warning field 2 is infringed.
(3) If this is configured as the output for "Reset required."
(4) f this is configured as the output for a contamination error/warning.
(5) If this is configured as the output for a contamination error.
(6) If this is configured as the output for a contamination warning.
Rockwell Automation Publication 442L-UM005B-EN-P - April 2017
23, the connections for the outputs of
System Connection on page
Possible Cause
Object in the protective field,
OSSDs in the OFF state
Protective field unoccupied,
OSSDs in ON state
Object in one of the warning
(1)
fields
(2)
No operating voltage or voltage
too low
(3)
Reset required
Restart delay is counting down.
(4)
No error
(5)
Optics cover contaminated, no
operation
(6)
Optics cover contaminated, still in
operation
62.
Corrective Action
No error
No error
No error
Check the voltage supply and
activate, if necessary.
Operate the control switch for
restart.
No action is required.
Clean the optics cover.
Clean the optics cover.