Chapter 5
Electrical Installation
Configuration Connection
M8 × 4 (Serial Interface)
64
Table 10 - Core Assignment of the SafeZone Mini Device Cable
Core
Color
1
White
2
Brown
3
Green
4
Yellow
5
Gray
6
Pink
7
Blue
8
FE/shield
Universal I/O Connections
ATTENTION: Do not use the universal I/O connection outputs for safety-
related tasks. The universal I/O connection outputs are purely application
diagnostics outputs, for example, for the transfer of information to
controllers.
Figure 39 - Pin Assignment
3
4
2
1
Table 11 - Pin Assignment Configuration Connection M8 × 4
Pin
SafeZone Mini Device
1
Reserved
2
RxD
3
0V DC (voltage supply)
4
TxD
After configuration:
• Always remove the connecting cable from the configuration connection.
• Locate the attached protection cap to cover the configuration
connection.
Rockwell Automation Publication 442L-UM005B-EN-P - April 2017
Function
Output for warning field 1
Supply voltage 24V DC
Universal I/O connection 1
Universal I/O connection 2
Output signal switching device OSSD1
Output signal switching device OSSD2
Supply voltage 0V DC
Functional earth/shield
PC-side RS-232-D-Sub
Not assigned
Pin 3
Pin 5
Pin 2