ATTENTION:
• Pay attention to the safety notes.
Observe the following items to verify the correct use of the SafeZone Mini
device.
• Repair only by authorized persons.
The improper repair of the protective device can result in the loss of the
protective function. Only the manufacturer or persons authorized by the
manufacturer can repair the protective device.
The SafeZone Mini device is of laser safety class 1. Additional measures for
screening the laser radiation are not necessary (eye-safe).
• This device meets the norms: IEC 60825-1, CDRH 21 CFR 1040.10
and 1040.11; excluded are deviations due to Laser Notice No. 50, dated
24.06.2007. In the standards CDRH 21 CFR 1040.10 and 1040.11 the
following note is required: "Caution – use of controls, adjustments or
performance of procedures other than those herein specified may result
in hazardous radiation exposure!"
• During the mounting, installation and usage of the SafeZone Mini
device, observe the standards and directives applicable in your country.
An overview of the most important regulations can be found in
Applicable Directives and Standards on page
• The national/international rules and regulations apply to the
installation, commission, use, and periodic technical inspections of the
SafeZone Mini device, including:
– Machinery Directive
– Work Equipment Directive
– The work safety regulations/safety rules
– Other relevant health and safety regulations
• Manufacturers and operators of the machine on which the SafeZone
Mini device is used are responsible for obtaining and observing all
applicable safety regulations and rules.
• The notes, in particular the test notes (see
in these operating instructions (for example, on use, mounting,
installation, or integration into the machine control) must be observed.
• Changes to the configuration of the devices can degrade the protective
function. After every change to the configuration, you must check the
effectiveness of the protective device. The person who makes the change
is also responsible for the correct protective function of the device.
When making configuration changes, always use the password hierarchy
that is provided by Rockwell Automation to verify that only authorized
persons change the configuration.