Resolution

The maximum protective field range
The following table shows the related maximum protective field range at the
resolutions that can be set:
Table 5 - Maximum Protective Field Range at Different Resolutions
Configured Resolution
[mm (in.)]
30 (1.2) – (hand detection)
40 (1.6) – (hand detection)
50 (2.0) – (leg detection)
70 (2.8) – (leg detection)
150 (5.9) (whole body detection)
IMPORTANT The warning field can be configured to up to 8 m (26.25 ft) for all
resolutions. The detection capability within the warning field is dependent
on the remission of the objects to be detected (see
on page

Basic Response Time

The basic response time of the SafeZone Mini device is 80 ms.
TIP You may need to add supplements to the basic response time due to
multiple sampling (see

Maximum Protective Field Range

Depending on the configured resolution that is used (see Resolution), the
maximum protective field range of the safety laser scanner is shown in the SCD
software.
ATTENTION: The maximum protective field range of the SafeZone Mini
device must be sufficient to cover the calculated protective field size
including the necessary supplements (see
(1) Radial distance to the safety scanner.
Rockwell Automation Publication 442L-UM005B-EN-P - April 2017
(1)
depends on the configured resolution.
Maximum Protective Field Range [m (ft)]
2 m (6.6 ft)
1.25 (4.1)
1.60 (5.2)
2.00 (6.6)
2.00 (6.6)
3.00 (9.84)
83).
OSSD Response Times on page
Protective Field Size on page
Configurable Functions
Chapter 3
3 m (9.8 ft)
1.25 (4.1)
1.60 (5.2)
2.10 (6.89)
3.00 (9.84)