Figure 3 - Field Set with One Protective Field and Two Warning Fields
Protective field
Warning field 1
Warning field 2
You can define the warning fields such that the safety laser scanner detects an
object before the actual hazardous area.
Warning field 1 can be used in particular for vehicle protection to detect an
object even before the actual hazardous area and to slow the movement of the
vehicle or bring it to a standstill. In this way, the wear on the brakes on an AGV
can be reduced. Warning field 2 can also be used to trigger a warning signal.
ATTENTION: A warning field on the SafeZone Mini device is not allowed to
be used for tasks that are related to the protection of people.