Fireplace Control Devices

There are three ways to control your fi replace.
1. Thermostatic Remote Control;
2. Manual On/Off Switch;
3. Wall Switch (optional) .
Thermostatic Remote
Wall Switch
Control
(optional)
The Thermostatic Remote Control can be programmed
to function automatically—see pages 8–12.
The manual On/Off switch must be ON for the fi replace
to function. It can be used to shut off the fi replace in
case of emergency—see below.
The Wall Switch (optional) can be used to turn on, off
and to increase or decrease the fl ame height—see
1265WSK or RBWSK—Wall Switch Kit.
NOTE: The remote control in the AUTO mode will
override the wall switch.
How to Turn Your Fireplace OFF (including
pilot)
Familiarize yourself with each of these methods before
operating your fi replace.
Handset and Wall Switch: Press and hold the OFF
button for a second (either on the handset or the wall
switch).
Remote control
handset
If the fl ames are on, they go down and you hear the
valve motor wind down. You hear a clunk and a beep
indicating that the valve has received the signal from
the remote control.

Operating Your Fireplace

ON
OFF
Manual On/Off Switch
Wall Switch
(optional)
In the unlikely event that you cannot turn off your
fi replace with the remote control handset, use the
wall switch (if installed); if the wall switch malfunctions
and will not turn off the fi replace, wait 6 hours and the
fi replace will automatically go to pilot. You can then
access the controls inside your fi replace. Alternately,
turn off gas supply. In all cases, call your dealer for
service assistance.
ON: parallel to pipe
How to Ensure Your Fireplace Cannot
Be Turned ON Inadvertently
You can use one of the two following methods to
ensure that your fi replace will not turn on when you
don't want it on.
WARNING
!
RISKS OF SEVERE BURNS! SURFACES OF
THE FIREPLACE ARE VERY HOT DURING
OPERATION! Be very careful and wear gloves to
access controls.
• You can prevent your fi replace from lighting by
pressing the O button on the manual ON/OFF
switch on the gas valve.
ON
OFF
Valve
Switch
• Alternately, you can remove all batteries from the
receiver as well as the battery from the handset.
Automatic Shut-Off (in certain conditions)
Your fi replace's remote control is equipped with an
automatic shut-off mechanism which is activated
in certain conditions. See page 12 in the Using the
Remote Control section for a description of this feature.
OWNER'S
INFORMATION
OFF:
perpendicular
to pipe
O
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Portrait 530ip