Figure 64: Control panel securing screws.
Figure 66: Control panel extracted from the unit.

Replacing the pilot assembly.

Extracting the pilot assembly requires that the control module be partially removed so that
there is room to withdraw and reinsert the pilot assembly wires and gas line, otherwise there
is not enough room to work with.
1. Release the control module by removing the two screws located at the top and the bottom of the control
module. This will provide room to extract and reinsert the pilot wires (X2 & X3 on the control module) and
pilot gas line through the square slot.
2. Disconnect the pilot gas line from the gas valve if not already removed.
3. Remove all of the connectors from the control module - including the ground wire, with the exception of
X1 (Line in connection) as these wires are long enough to provide the needed room to move the control
module aside.
060718-44
Figure 65: Remove lower screw.
Figure 67: Line in connections.
37
100000432-50