Verify the pilot ame by turning the adjustment screw, using a at-tip
screwdriver, seen on the valve in Figure 4434.
060718-44

Pilot Adjustment

Figure 43: Valve & IFC module location.
PILOT ADJUSTMENT
SCREW
PRESSURE
MANIFOLD PRESSURE
MODULATOR
TEST POINT
DEVICE
Figure 44: Gas control valve.
PILOT
MAIN GAS
SOLENOID
SOLENOID
INLET
PRESSURE
TEST POINT