Electrical Data - Edwards EPX HiVac Series Instruction Manual

Dry vacuum pumps
Hide thumbs Also See for EPX HiVac Series:
Table of Contents

Advertisement

A419-00-880 Issue F
2.3

Electrical data

Electrical items
Electrical supply
Voltage tolerance
Electrical power
Maximum Power
Nominal Power at Ultimate (EPX)
L-variant
N-variant
Nominal Power at Ultimate (EPX twin)
L-variant
N-variant
*
Fuse/ isolator rating
200 V
400 V
Installation (overvoltage) category
Pollution degree
Minimum protective earth (ground) cable rating
Electrical supply interface
Power cable
TIM
Parallel pump interface
Nominal voltage rating
Shut-down thermal snap-switch
Opening temperature
Closing temperature
*
Maximum recommended fuse rating; requires a multipole isolator with a minimum contact gap of 3 mm.
The mains disconnect device AIC (Amperes Interrupting Capacity) must be rated to at least 10 000 A.
See clause 13 of SEMI S2 - 0200 and SEMI S8 for further details.
Page 16
Table 8 - Electrical data
Reference data
200/208 V, 50/60 Hz, 400 V 50/60 Hz 3-phase
±10%
3.0 kW
1.4 kW
1.6 kW
2.30 kW
2.55 kW
17.5 A current limiting time delay Class CC fuse, rated 600 V
10 A current limiting time delay Class CC fuse, rated 600 V
Class II
2
32 A
Per customer specification
4 core terminated with 2.5 mm
As per TIM interface supplied (refer to
24 V
o
o
70
C, 158
F
o
o
59
C, 138
F
Edwards and the Edwards logo are trademarks of Edwards Limited.
2
bootlace ferrules
Section