Specifications
Minimum ambient temperature during full-scale operation
Minimum ambient temperature at reduced performance
Temperature during storage/transport
Maximum altitude above sea level without derating
Maximum altitude above sea level with derating
1) For more information on derating, see section on special conditions in the Design Guide.
EMC standards, Emission
EMC standards, Immunity
Energy efficiency class
2) Determined according to EN50598-2 at:
Rated load.
90% rated frequency.
Switching frequency factory setting.
Switching pattern factory setting.

8.5 Cable Specifications

Cable lengths and cross-sections for control cables
8
8
Maximum motor cable length, screened/armoured
Maximum motor cable length, unscreened/unarmoured
Maximum cross-section to motor, mains, load sharing, and brake
Maximum cross-section to control terminals, rigid wire
Maximum cross-section to control terminals, flexible cable
Maximum cross-section to control terminals, cable with enclosed core
Minimum cross-section to control terminals
1) For power cables, see electrical tables in chapter 8.1 Electrical Data.

8.6 Control Input/Output and Control Data

Digital inputs
Programmable digital inputs
Terminal number
Logic
Voltage level
Voltage level, logic 0 PNP
Voltage level, logic 1 PNP
Voltage level, logic 0 NPN
Voltage level, logic 1 NPN
Maximum voltage on input
Input resistance, R
All digital inputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
1) Terminals 27 and 29 can also be programmed as outputs.
Analog inputs
Number of analog inputs
Terminal number
Modes
Mode select
Voltage mode
Voltage level
Input resistance, R
Maximum voltage
Current mode
Current level
64
VLT® AutomationDrive FC 302
2)
i
i
Danfoss A/S © 06/2015 All rights reserved.
1)
0 °C
10 °C
-25 to +65/70 °C
1000 m
3000 m
EN 61800-3
EN 61800-3
IE2
150 m
300 m
1.5 mm
2
/16 AWG (2x0.75 mm
1 mm
2
/18 AWG
2
0.5 mm
/20 AWG
0.25 mm
4 (6)
1)
1)
18, 19, 27
, 29
, 32, 33
PNP or NPN
0–24 V DC
<5 V DC
>10 V DC
>19 V DC
<14 V DC
28 V DC
approximately 4 kΩ
53, 54
Voltage or current
Switches A53 and A54
Switch A53/A54=(U)
-10 V to +10 V (scaleable)
approximately 10 kΩ
±20 V
Switch A53/A54=(I)
0/4 to 20 mA (scaleable)
MG34U402
2
)
2
2

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 302 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF