This receiver accepts infrared signals of from 30 kHz to 300 kHz.
The IR remote control must be pointed directly at the receiver
for best results. The diagram at right indicates the best
distances and angles at which to hold the remote control.
Mounting the IPL Pro Series

Mounting Options

Optional 1U high rack shelves and a variety of rack mounting bracket kits and furniture
mounting kits are available for use with the IPL. The one inch high model requires different
brackets than the 1U high models. Visit the product-specific page on the Extron website
(www.extron.com) for a list of compatible accessories for mounting your control processor
or call a support representative to find out which kit to order for your installation. Read the
instructions that are included with the rack shelf or mounting kit for installation procedures
and see the UL rack mounting guidelines.

UL Rack Mounting Guidelines

The following
the IPL Pro Series in a rack.
1.
2.
3.
4.
5.
Underwriters Laboratories (UL)
Elevated operating ambient temperature — If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient temperature. Therefore, install the IPL in an environment compatible
with the maximum ambient temperature (Tma = +122 °F, +50 °C) specified by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
Mechanical loading — Mount the equipment in the rack so that a hazardous
condition is not achieved due to uneven mechanical loading.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as use of power strips).
guidelines pertain to the safe installation of
IPL Pro Series • Hardware Features and Installation
IR
IR Receiver
IR Learning Angle
and Distance
2–12"
(4–30 cm)
1
2
3
4
5
6
7
8
9
0
12