Connecting Peripherals; Input Connections - Pyronix PCX 78 Installation Manual

Table of Contents

Advertisement

Fuses
230 V mains fuse for mains terminals
The battery connect 'kickstart' button is used to power-up the control panel when there is no mains
supply present. For example: if you wish to program a panel that is being fitted in a new-build
premises before the mains supply has been fully installed. To use it – Hold for 5 seconds and then
release.
For more information, see "The Printed Circuit Board" on page 17
Ensure that the battery jumper is in the correct position for the capacity of battery that you
have connected – otherwise the panel may under-charge a large battery or over-charge and
damage a smaller battery.

Connecting Peripherals

Input Connections

If 'Normally Closed' (double pole) wiring is selected, the diagnostics on the keypad will show
1K Alarm and 1K Tamper .
Input resistance
Normal
Burglary alarm
PCX Installation Guide
Value
T500mA H anti-surge slow blow 250 V
1k / 1k DEOL Range
4k7 / 2k2 DEOL Range
0k5 to 1k4
1k4 to 2k9
1k5 to 5k9
4k2 to 7k8
102017852 - V01
Type
Ceramic
4k7 / 4k7 DEOL Range
3k7 to 8k3
8k4 to 10k2
21