INSTALLATION INSTRUCTIONS Manual Type 6.4.0.7-RF TES2 with Essex Wiegand Keypad For Models 400-W-TES2 401-W-TES2 403-W-TES2 404-W-TES2 410-W-TES2 411-W-TES2 Specifications Communication Access Control TES2 telephone entry system provides a Essex KPT-26TI 26 bit Wiegand Keypad communication link between the front door and every TES2 can open 2 doors with optional T-RLY phone in the house.
Page 2
TES2 Wiring Diagram Door 1 Door 2 NOTE: Voltage from telephones is not nec- NC1 C NO1 NC2 C NO2 essary for the system to work. (See note ‘‘No CO operation”) No Ring Jumper The connection between the main board and the speaker board is polarity sensitive.
Page 3
When the “NO RING” option is selected, the phones will not ring. When the homeowner hears the external door chime (not supplied by Holovision), and then picks up any telephone, they will be automatically connected to the door phone.
Page 4
TES2 Telephone Entry System Door Ring Patterns Door 1 3 groups of 3 rings (ring ring ring), (ring ring ring), (ring ring ring). Door 2 3 groups of 2 rings (ring ring), (ring ring), (ring ring). Operation of TES2 ANSWER THE CALL When you heat the distinctive ring pattern selected above: within 10 seconds - simply pick up any telephone to be connected to the door speaker which initiated the call.