6 Troubleshooting and Remedies

6 Troubleshooting and Remedies
Observe the safety instructions! Faults on the machine or on the engine
that make a major intervention necessary must always be repaired by a specialist
agria workshop that have the necessary tools. Incorrect intervention will only lead to
damage.

Remote control

Fault
Possible cause
The green LED of
The rechargeable battery is
the FB does not
flat
light up when
pressing the un-
locking button. The
rechargeable bat-
tery and the key
switch are inserted.
The green LED of
No radio connection
the remote control
flashes rapidly.
The red LED of the
The transmitter is not working
remote control
correctly.
illuminates for 2
seconds and then
the remote control
switches off.
The red LED of the
The EMERGENCY STOP
remote control
switch is actuated or defec-
flashes once during
tive.
startup.
The red LED of the
At least one of the operating
remote control
elements relating to the com-
flashes twice dur-
mands D2-D20 and SAFETY
ing startup.
is active or defective.
The red LED of the
The battery is flat.
remote control
flashes three times
during startup.
The red LED of the
At least one of the operating
remote control
elements relating to the com-
flashes four times
mands A1-A8, L1-L8, H1-H8
during startup.
and SAFETY is active or
defective.
See remote control operating
instructions
Remote-controlled High Grass Rotary Mulcher agria 9600-112
Remedy
Insert charged rechargeable
battery.
Move the transmitter closer to
the receiver unit
Save the address:
- Press EMERGENCY STOP
- Press and hold release button
until green LED goes out
- Release EMERGENCY STOP
- agria-Service -
Deactivate EMERGENCY STOP
switch. If the message remains
- agria-Service -
Return the operating elements to
normal position. If the message
remains
- agria-Service -
Insert charged rechargeable
battery.
Return the operating elements to
normal position. If the message
remains
- agria-Service -