3.1 . Materials
The F1-ClipTip is made of mechanically durable and chemically resistant materials.
For waste disposal instructions, contact your local environmental agency. For more information,
contact us at info.pipettes@thermofisher.com.
Aggressive substances can damage the pipette or pipette parts. Check for material
compatibility before using organic solvents and aggressive chemicals.
ClipTip pipette tips are made of natural color virgin polypropolyene. The tips feature a hydrophobic
surface, which effectively prevents liquid retention. ClipTips pipette tips come in multiple packaging
options including racks and reload packs, in sterile and non-sterile versions. ClipTip tips are also available
with a filter and are certified free of human DNA, RNase, DNase, ATP and endotoxin contamination.
The material used in F1-ClipTip pipettes and ClipTip tips are as follows:
F1-CLIPTIP PIPETTES
Material
External surfaces of the upper parts:
ABS/PC
PA
PEI
Foil
Exterior and interior of lower parts:
PEI
PA
PVDF
EPDM
FVM
Steel
PPSU
CLIPTIP TIPS
Tip
PP
Filters
PE
Cautions are marked with this symbol
4.1. Intended use
The intended use of the device is to transfer liquids in the volume range of 0.1 µl to 1000 µl.
The F1-ClipTip pipette and ClipTip tip are designed as a component of an analyzing system for an end
user, who is responsible for validating the system to ensure reliable and safe results.
Damage to health
Follow general procedures for hazard prevention and safety instructions; e.g. wear
protective clothing, eye protection and gloves.
For use and waste disposal of hazardous (e.g. radioactive and potentially infectious) material,
follow the safety instructions and general laboratory practice.
The pipette and tips are not intended for in vivo use. Do not use the pipette for pipetting any liquid
to be injected into a human body.
Do not eject the tip towards anybody.
The F1-ClipTip is to be used by trained personnel with required laboratory skills. The instructions for
use must be read prior to and during the use of the device (pipette and tip). The F1-ClipTip pipette can
be used between +4°C and +40°C.
acrylonitrilebutadienstyrene/polycarbonate
polyamide
polyetherimide
polyetherimide
polyamide
polyvinyldenfluoride
ethylene-propylene-diene rubber
fluorosilicone rubber
stainless steel
Polyphenylsulfone
polypropylene
polyethylene

4. Safety

.