Thermo Scientific FH15 Operating Manual

Compact pump systems

Advertisement

Quick Links

FH15 & FH30
COMPACT PUMP
SYSTEMS
Operating Manual
Model Number
72-315-100
72-330-100
A-1299-7100 First Edition

Advertisement

Table of Contents
loading

Summary of Contents for Thermo Scientific FH15

  • Page 1 FH15 & FH30 COMPACT PUMP SYSTEMS Operating Manual Model Number 72-315-100 72-330-100 A-1299-7100 First Edition...
  • Page 2 VITON – Reg TM E.I. duPont DeNemours & Co. Trademarks bearing the symbol in this publication are registered in the U.S. and in other countries. ® A-1299-7100 EC16696 091201 First Edition ECR/ECN DATE DESCRIPTION Thermo Scientific FH15 & FH30 Compact Pump System Operating Manual...
  • Page 3 Tubing breakage may result in fluid being sprayed from pump. Use appropriate measures to protect operator and equipment. CAUTION: Tubing for use with the FH15 and FH30 Compact Pump Systems are two-stop tubing sets. See Appendix A for specifics. Use of tubing sets other than that specified will result in poor pumping performance and/or pump system damage and voiding of applicable warranty.
  • Page 5: Table Of Contents

    APPENDIX A ..........8-1 Thermo Scientific FH15 & FH30 Compact Pump System Operating Manual...
  • Page 7 Page FH15 & FH30 Compact Pump System .......1-1 Pump – Front Panel ..........1-2 Pump –...
  • Page 9: Introduction

    Introduction Section 1 GENERAL The FH15 & FH30 Compact Pump Systems, Figure 1-1, are enclosed in a painted steel and anodized aluminum housing. DESCRIPTION Tubing Retainer Bracket Occlusion Bed Universal Power Supply Latch Figure 1-1. FH15 & FH30 Compact Pump System The Pump System can accommodate one or two tubes simultaneously (depending on model) at controlled speeds as low as 20 rpm.
  • Page 10 4-terminal barrier strip for connection of Remote Start/Stop and for a remote DC supply. DC Power Input, 2.5 mm Coaxial Receptacle Remote Input Remote Start/Stop Input Shorting Bar Figure 1-3. Pump — Rear Panel FH15 & FH30 Compact Pump System Operating Manual Thermo Scientific...
  • Page 11: Installation And Setup

    Appendix A provides a list of tubing sets which will work efficiently with Selecting Tubing Size the FH15 & FH30 Compact Pump System. This list includes tubing diameters, flow rates in mL/min and the maximum flow rates per revolution at 20 rpm and 100 rpm. Tubing is listed by part number. For best results, when using two tubes (two-channel models only), select tubes that provide flow rates within a 10:1 range.
  • Page 12: Connecting Primary Power

    3 and 4. A closure of the remote control switch contacts will start the Pump System. Opening the contact will stop the Pump System. FH15 & FH30 Compact Pump System Operating Manual Thermo Scientific...
  • Page 13: Operation

    Priming Pump System Push Button is used for priming and purging the Pump System. When is depressed, the pump operates at maximum speed in the selected direction until the button is released. Thermo Scientific FH15 & FH30 Compact Pump System Operating Manual...
  • Page 15: Maintenance

    1500 operating hours minimum. Operation at other than continuous duty cycles will result in longer motor life. If motor failure for whatever reason occurs, the motor must be replaced. Thermo Scientific FH15 & FH30 Compact Pump System Operating Manual...
  • Page 17: Replacement Parts

    Replacement Parts Section 5 Replacement Parts Description Part No. Rubber feet (pkg. of 4) A-1390-0001-CR Knob 110199 Shorting Bar A-4402 Universal power adapter 77200-07 Thermo Scientific FH15 & FH30 Compact Pump System Operating Manual...
  • Page 19: Specifications

    EN61326-1/A2: 2001 (EMC Directive) 2002/95/EC (RoHS Directive) Converter is UL, cUL listed and CE, CCC approved. Regulatory agency specifications not applicable to the balance of the unit due to low voltage. Thermo Scientific FH15 & FH30 Compact Pump System Operating Manual...
  • Page 21: Warranty, Product Return And Technical Assistance

    WARRANTY. IN NO EVENT SHALL THE MANUFACTURER OR DISTRIBUTOR BE LIABLE FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES. The warranty period for this product is one (1) year from date of purchase. Thermo Scientific FH15 & FH30 Compact Pump System Operating Manual...
  • Page 22: Product Return

    Any damages resulting from improper packaging are your responsibility. Technical Assistance If you have any questions about the use of this product, contact the Manufacturer or authorized seller. FH15 & FH30 Compact Pump System Operating Manual Thermo Scientific...
  • Page 23 Appendix A Section 8 CAUTION: Tubing for use with the FH15 & FH30 Compact Pump Systems are two-stop tubing sets. Use of tubing sets other than that specified will result in poor pumping performance and/or pump system damage and voiding of applicable warranty.
  • Page 24 9001 Thermo Fisher Scientific REGISTERED SUPPLIER 28W092 Commercial Ave. Barrington, Illinois U.S.A. 60010-2392 1-800-637-3739 (U.S. and Canada only) 11 (847) 381-7050 (Outside U.S.) (847) 381-7050 (Local) www.thermo.com fluidhandling@thermofisher.com...

This manual is also suitable for:

72-315-10072-330-100Fh30