Lamp Replacement

When the life of the projection lamp of this projector draws to an end,
the LAMP REPLACE indicator lights yellow. If this indicator lights
yellow, replace the lamp with a new one promptly.
CAUTION
Allow a projector to cool, for at least 45 minutes before
you open the Lamp cover. The inside of the projector
can become very hot.
Follow these steps to replace the lamp.
1
Turn off the projector and disconnect the AC plug. Allow the
projector to cool for at least 45 minutes.
2
Turn over the projector. Loosen the screw with a screwdriver,
and remove the lamp cover.
3
Loosen 2 screws of the lamp with a screwdriver and pull out the
lamp by grasping the handle.
4
Replace the lamp with a new one and tighten the 2 screws back
into position. Make sure that the lamp is set properly. Replace
the lamp cover and tighten the screw.
5
Connect the AC power cord to the projector and turn on the
projector.
6
Reset the Lamp replace counter.
See "Lamp Replace Counter" on the next page .
ORDER REPLACEMENT LAMP
Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information
to the dealer.
G
Model No. of your projector
G
Replacement Lamp Type No.
Maintenance and Cleaning
This indicator lights yellow
when the life of the projection
lamp draws to an end.
CAUTION
For continued safety, replace with a lamp of the same
type. Do not drop a lamp or touch a glass bulb! The
glass can shatter and may cause injury.
:
PLV-Z2
:
POA-LMP69
(Service Parts No. 610 309 7589)