Technical Data; Receiver Functionality - Tele Radio R00008-22 Installation Instructions Manual

Industrial radio remote controls, receiver/transmitter
Table of Contents

Advertisement

TECHNICAL DATA

 
Number of function relays
Digital inputs
Number of DC motor controls
Number of analogue outputs
Number of analogue inputs
Duplex communication
Min./max. current consumtion
Operating frequency
Number of radio channels
Channel separation
IP class
Size
Weight
Antenna
 
* potential free means that you have to supply voltage to get voltage out of a
relay (e.g. via the included connection comb)
 
** Minimum current consumption= Receiver on, no radio communication
established, sleep mode activated.
*** Maximum current consumption= Maximum output (10A) on motor 1
output and maximum output (10A) on motor 2 output.
 
 

RECEIVER FUNCTIONALITY

PRESS BUTTON:
1
2
3
4
5
6
 
1 (potential free*, 8A)
8
2
2
2
No
12 V DC: Min.** 0.5mA/ Max.*** 20A
24 V DC: Min.** 0.5mA/ Max.*** 20 A
2405-2480 MHz
16 (channel 11-26)
5 MHz
66
121 x 117 x 51 mm./ 4.75 x 4.6 x 2 in.
420 g./ 0.926 lbs.
1 internal
RESULTS IN:
The PWM output between M1A and M1B will be positive and increase to
the same voltage level as the input between (+) and (-).
The PWM output between M2A and M2B will be positive and increase to
the same voltage level as the input between (+) and (-).
The relay will be active, and the PWM output between M2A and M2B will
be positive and increase to the same voltage level as the input between
(+) and (-).
The PWM output between M1A and M1B will be negative and increase to
the same voltage level as the input between (+) and (-).
The PWM output between M2A and M2B will be negative and increase to
the same voltage level as the input between (+) and (-).
The relay will be active, and the PWM output between M2A and M2B will
be negative and increase to the same voltage level as the input between
(+) and (-).