Rectifying faults
Error messages
7.2
Error messages
A welding machine error is indicated by the collective fault signal lamp (A1) lighting up and an
error code (see table) being displayed in the machine control display. In the event of a machine
error, the power unit shuts down.
The display of possible error numbers depends on the machine version (interfaces/functions).
•
Document machine errors and inform service staff as necessary.
Error message
Err 3
Err 10
Err 34
7.3
Resetting welding parameters to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
Operating
element
60
Possible cause
Speedometer error
PE error
Hot wire inverter
Action
Result
Switch off the welding machine
Keep the push-button pressed
Switch on the welding machine
Release the push-button
Wait about 3 seconds
Switch off the welding machine and restart in
order to put the changes into effect.
Remedy
Check wire guide/hose package
Switch the machine off and on again.
If the error persists, notify the service
department.
Switch the machine off and on again.
If the error persists, notify the service
department.
left
099-000236-EW501
Display
right
21.10.2015
Need help?
Do you have a question about the tigSpeed continuous drive 45 hotwire and is the answer not in the manual?