EWM tigSpeed continuous drive 45 hotwire Operating Instructions Manual page 21

Hide thumbs Also See for tigSpeed continuous drive 45 hotwire:
Table of Contents

Advertisement

Item Symbol
1
2
3
4
5
6
7
8
099-000236-EW501
21.10.2015
Machine description – quick overview
Description
0
Lid - See 4.4.1 Machine control – Concealed operating elements chapter
Push-button for switching the wire feed speed display
m/min
Wire feed speed in meters per minute.
ipm
Wire feed speed in inch per minute.
Display, left
Wire feed speed
Rotary dial, welding parameter setting
To set the wire feed speed and other welding parameters.
Operating mode selection push-button
Non-latched, manual
Latched, manual
Non-latched, automatic
Latched, automatic
Signal light lights up in red: TIG tack welding
Rotary knob to set the parameters for hot wire current/program number
Selection of the hot wire current 40 A–180 A
Selection of the program number
Display switching push-button
Prog
Program number display
AMP Hotwire
Hot wire current display
Display, right
Hot wire current, program number
Machine control – Operating elements
21