Com Ports - Intermec 5055 User Manual

Data collection pc
Hide thumbs Also See for 5055:
Table of Contents

Advertisement

SECTION 3
System Setup
"

COM Ports

The COM Ports option lets you set up the port address and
interrupt for two serial (COM) ports. The factory default
has both COM port settings set to "None."
1. Press <Alt>, [C], [C] from the SCU screen to access
2. Press <Tab> two times to move the cursor into the
3. Press one of the following for the first COM port:
" NOTE:
An option is selected when a dot appears in parentheses in front of
that option: "(S)"
4. Press <Tab> to move the cursor into the "COM B Set-
5. Press one of the following for the second COM port:
" NOTE:
An option is selected when a dot appears in parentheses in front of
that option: "(S)"
6. Press <Enter> to exit the "COM Ports" menu and
3-4
5055 Data Collection PC User's Guide
the "COM Ports" menu and set the port address and
interrupt settings.
"COM A Settings" box to select the port address and
interrupt for the first internal COM port.
[N] None
"
[1]
COM 1, 3F8, IRQ 4
"
[2]
COM 2, 2F8, IRQ 3
"
[3]
COM 3, 3E8, IRQ 4
"
[4]
COM 4, 2E8, IRQ 3
"
tings" box to select the port address and interrupt for
the second internal COM port.
[N] None
"
[1]
COM 1, 3F8, IRQ 4
"
[2]
COM 2, 2F8, IRQ 3
"
[3]
COM 3, 3E8, IRQ 4
"
[4]
COM 4, 2E8, IRQ 3
"
save your selections.

Advertisement

Table of Contents
loading

Table of Contents