Maintenance
9.4 Repair
Disassembly
● Once the coupling is detached, you can remove the protective ring from the shaft. After it
Assembly
● Push the protecting ring over the end of the shaft. Make sure that the outer collar is placed
9.4.5

Removing and mounting the bearing shields

1. Unscrew the belt pulleys. The belt pulleys may be jammed or distorted, in which case you
2. Remove the bearing shield.
For assembly, proceed in reverse order.
9.4.6

Installing the machine

Strictly ensure the greatest possible care and cleanliness when repairing the machine.
106
has been removed, the protective ring will be deformed and must be replaced.
at a spacing of 1 mm from the bearing end shield.
Figure 9-2
Fitting the protecting ring
should lever them off carefully.
When removing the bearing shields, take care that the windings are not damaged.