FIGURE 6.10 SINGLE ELECTRIC pOWERED STEAm GENERATOR ASSEmBLY
6.10 SOLENOID FILL VALVE STRAINER SCREEN CLEANING
The solenoid fill valves contain a built in strainer screen inside
the valve body. This screen must be removed and cleaned pe-
riodically (depending on usage and water quality) to remove
any debris or line build-up which will accumulate during normal
operation. The procedure is as follows:
1.
Remove the left large side panel by removing the screw
from the center of the bottom edge of the panel. Gripping
one of the louvers, slide the panel upwards until the bot-
tom edge of the panel is free to swing away from the unit.
Slide the panel down until its top edge is clear of the top
cap of the unit.
6. MAINTENANCE
6.14
2.
Unscrew screen plug from valve and remove screen.
3.
Clean screen and reassemble screen and screen plug into
valve body.
4.
Replace large side panel by placing the panel against the
side of the unit. Be sure that the top edge of the side panel
slides under the top cap of the unit. Slide the panel up-
wards until it stops. Then while pushing the panel towards
the unit, slide it down into position. Replace screw.