Door Latch Tension Adjustment - Market Forge Industries STEAM-TECH PLUS STP-6E Owner's Manual

Electric steam cooker
Table of Contents

Advertisement

7.
Square the door to the unit by rasing or lowering the hinge
side of the door keeping the latch centered with the strik-
er.
8.
Visually inspect the door. Be sure that the door is square
to the unit the striker is centered with the latch and the
gasket is in contact with the entire lip of the cooking com-
partment.
9.
Gently open the cooking compartment door taking care not
to move it out of position.
10.
Tighten all 4 door hinge bracket mounting bolts, using a
6. MAINTENANCE
FIGURE 6.7 CONTROL pANEL ASSEmBLY
6.10
5/16" wrench.
11.
Close and visually inspect the door again as described in
step 8.

6.8.2 DOOR LATCH TENSION ADJUSTMENT

The cooking compartment door latch tension is preset at the
factory and should not need adjusting unless the doors are
revered. Should the latch need adjusting the procedure is as
follows:
1.
Open the cooking compartment door.
2.
If latch is mounted on the right side of the cooking compart-

Advertisement

Table of Contents
loading

Table of Contents