Power Meter; String Monitoring (120&122 Models) - Delta M42U Operation And Installation Manual

Grid-tie transformerless solar inverter
Table of Contents

Advertisement

4.3.1 Power meter

This page displays voltage, current and power measurements from both the
AC and DC side.
4.3.2 String monitoring (120&122 models)
The string current monitoring function is accessed via the Power Meter menu
Four sub-pages are accessed using display keys as shown in Figure 4-4, two
pages display string current values for the nine strings of MPPT1 and MPPT2.
AC
V 480
I
50.5
P 13989
PF
Power.
Frequency:
E-Today:
DC
V
I
P
Figure 4-4: Power Monitoring and String Current Monitoring
L1
L2
L3
480
480
V
50.5
50.5
A
13989
13989
W
or
ENT
0.9
41966
kW
:
60.00
Hz
147
kWh
or
ENT
DC1
DC2
545
545
V
40.0
40.0
A
21800
21800
W
or
ENT
IDC1
1:
8.0
2:
8.1
3:
7.9
IDC2
1:
8.0
2:
8.1
3:
7.9
55
Commissioning
(A)
4:
8.0
5:
8.1
6:
8.0
or
ENT
(A)
4:
8.0
5:
8.1
6:
8.1

Advertisement