Procedures To Remove Pm Air Inlet Filter - Delta M42U Operation And Installation Manual

Grid-tie transformerless solar inverter
Table of Contents

Advertisement

Maintenance

5.4.1.2 Procedures to remove PM air inlet filter

Refer to Figure 5-13. Filter can be removed from either side of PM:
1. Unlatch the retaining hook and grasp the filter handle.
2. Carefully pull the filter frame straight out keeping it perpendicular to the side
of the PM chassis.
3. Clean the filter with warm water and allow to dry.
Reverse the above procedure to re-install the filter. When filter assembly is in
proper position, the retaining hook should be latched to the rail.
Figure 5-13: Removing the PM air inlet filter