P(V) - Delta M42U Operation And Installation Manual

Grid-tie transformerless solar inverter
Table of Contents

Advertisement

Commissioning

4.3.8.3 P(V)

When grid voltage rises up to a lock-in voltage(V lock-in) and inverter's present
output power is greater than lock-in power(P lock-in), inverter will reduce the
output power and keep it at a certain value(P lock-out) until grid voltage drop
back to lock-out voltage(V lock-out) and passing a certain time(T recovery).
Power Limit
Power vs. Frequency
P(V)
P
Pm
f
start =
Figure 4-24: Power vs Frequency parameter
Figure 4-25: P(V) screens
Gradient
f
f
recovery
protection
Mode
ENT
P lock-in
P lock-out
V lock-in
EXIT
V lock-out
T recovery
EXIT
66
f
( Hz )
OFF
20%
5%
528.2V
519.6V
300s

Advertisement

Table of Contents
loading

This manual is also suitable for:

M36uM28uM80uM60u

Table of Contents