Connecting an external sensor or motion detector

Connecting a potential-free opener contact as per + 12 V (NC mode).
NOTE
When connecting several motion detectors or sensors to this input, the switch contacts in this
mode must be switched in series.
Connecting a potential-free closer contact as per + 12 V (NO mode).
NOTE
When connecting several motion detectors or sensors on this input, the switch contacts in this
mode must be switched in parallel.
pink (6)
12 V
Control input
Setting mode in menu
or
Switching signals:
Switching signal if menu
(Menu
= Automatic closing)
pink (6)
12 V
Control input
Setting mode in menu
or or or or or
Switching signals:
Switching signal if menu
(Menu
= Automatic closing)
Potential-free
opener contact
:
OPEN - STOP- CLOSE - STOP...
is enabled:
OPEN (opening)
Potential-free
closer contact
:
OPEN - STOP- CLOSE - STOP...
is enabled:
OPEN (opening)