Brief Description Of Control Inputs - RADEMACHER RolloSystems T2 Instruction Manual

Table of Contents

Advertisement

Brief description of control inputs

14
A
Connection of external controls
The drive has two control inputs A
such as:
Sensor
Motion detector etc.
Roller shutter switch
Colour assignment of the drive cable for the control inputs
Drive cable
Assignment
white (3)
= control input A
yellow (4)
= control input B
Setting the function of the control inputs (see page 34)
The function of each control input can be set as needed. This is done in menus
The following functions can be set:
Off
NC mode (potential-free opener contact)
NO mode (potential-free closer contact)
Pause mode (potential-free closer contact)
Opening, potential-free closer contact
(dead-man operation, e.g. for roller shutter switches)
Closing, potential-free opener contact
(dead-man operation, e.g. for roller shutter switches)
Permissible voltage for control inputs
Input voltage:
Input resistance:
IMPORTANT
Control inputs not in use must be connected to GND, brown (1) or grey (2).
and B
and B
for connecting various external controls,
9 V to 24 V
> 47 kΩ
GB
and
.

Advertisement

Table of Contents
loading

Table of Contents