Service and Repair Manual
Control System
Screen or Menu
Primary Lift Speeds
Extend Thresholds
Retract Threshold
Up Threshold
Down Threshold
Extend Max
Retract Max
Up Max
Down Max
Screen or Menu
Primary Lift Ramps
Extend Accelerating Rate
Extend Decelerating Rate
Retract Accelerating Rate
Retract Decelerating Rate
Up Accelerating Rate
Up Decelerating Rate
Down Accelerating Rate
Down Decelerating Rate
Screen or Menu
Turntable Speeds
Rotate CW Max
Rotate CCW Max
Rotate CW Threshold
Rotate CCW Threshold
CW Out of Stow Max
CCW Out of Stow Max
28
Item
190% max, 50% min, 100% = 506 mA (default)
251% max, 50% min, 100% = 329 mA (default)
195% max, 50% min, 100% = 620 mA(default)
196% max, 50% min, 100% = 616 mA (default)
150% max, 68% min, 100% = 1425 mA (default)
150% max, 63% min, 100% = 1323 mA (default)
150% max, 68% min, 100% = 1800 mA (default)
150% max, 68% min, 100% = 1800 mA (default)
Item
5000 ms max, 1000 ms min, 2500 ms (default)
5000 ms max, 250 ms min, 1000 ms (default)
5000 ms max, 1000 ms min, 2500 ms (default)
5000 ms max, 500 ms min, 1000 ms (default)
5000 ms max, 1000 ms min, 3000 ms (default)
5000 ms max, 500 ms min, 3000 ms (default)
5000 ms max, 1000 ms min, 3000 ms (default)
5000 ms max, 1000 ms min, 1000 ms (default)
Item
150% max, 74% min, 100% = 1210 mA (default)
150% max, 74% min, 100% = 1210 mA (default)
125% max, 50% min, 100% = 580 mA (default)
125% max, 50% min, 100% = 580 mA (default)
150% max, 83% min, 100% = 881 mA (default)
150% max, 83% min, 100% = 881 mA (default)
®
S
-60 XC
• S
Default
Default
Default
®
-65 XC
September 2018
Part No. 1288652GT