Control System Fault Codes
ID
Component
ID
36 Incorrect
83
Telematics
21 Remote
84
Turntable Tilt
13 Not
Sensor
17 Invalid
ID
Component
ID
88
Function
12 Circuit
Enable Valve
15 Circuit
110
Name
Cause
TCON's
software
secondary
version
processor
software revision
does not match
the system
revision level.
The telematics
disable
module has
locked out
machine
operation.
The tilt sensors
detected
(S8O and/or S8S)
have not been
detected on the
CAN bus.
The tilt sensors
calibration
have no valid
calibration data,
either because
the sensor(s)
were replaced or
the prior
calibration was
cleared from
memory or was
unsuccessful.
Name
Cause
TCON detected
shorted to
that C155PCE
V+
circuit is shorted
to 12 V.
TCON detected
®
S
-60 XC
Effect
Solution
short circuits if resistance check fails.
* Replace TCON if necessary.
Reprogram the machine with latest
software. Check
http://firmware.genielift.com/ for the latest
software version.
Machine will
Call machine owner to re-enable machine
not be
functions.
functional, or
have limited
functionality,
depending
on the
telematics
option.
Boom Up,
* Verify S8O is receiving power.
Extend and
Disconnect sensor connector and verify
Drive
harness connector pins 1 and 2 measure
12 V.
functions will
not operate.
* Verify S8S is receiving power.
Disconnect sensor connector and verify
harness connector pins 1 and 2 measure
12 V.
* Verify CAN bus wiring. With a voltmeter
set to resistance, check the resistance
between pins 3 and 4 on the harness
connector (not the sensor's integrated
connector). Resistance should be
between 55 and 65 ohms. Check CAN
wiring if resistance check fails.
* Replace sensor if required.
Boom Up
Perform the tilt sensor calibration process.
and Extend
functions will
not operate.
Effect
Solution
Only
* With a voltmeter, measure Y74. Proper
Auxiliary
resistance should be between 5 - 60 ohms.
Power is
Replace Y74 if resistance is outside of
available.
those values.
* Verify wiring for C155PCE (OR/RD,
TCON J2-5) and check for open or short
®
• S
-65 XC
September 2018
Part No. 1288652GT