Genie S-65 XC Service And Repair Manual page 119

Serial number range from s65xcm-101
Hide thumbs Also See for S-65 XC:
Table of Contents

Advertisement

September 2018
ID
Component
ID Name
34 Incorrect
36 Secondary
79
Display
13 Not
Controller
(DISCON)
34 Incorrect
ID
Component
ID Name
80
Turntable
13 Not
Controller
(TCON)
Part No. 1288652GT
Cause
PCON software
software
revision does not
version
match the system
revision level.
TCON has not
processor
detected the
not
PCON secondary
detected.
processor on the
communications
bus.
TCON has not
detected
detected the
DISCON on the
communications
bus.
DISCON software
software
revision does not
version
match the system
revision level.
Cause
The DISCON has
detected
not detected the
TCON on the
CAN bus.
®
S
-60 XC
Control System Fault Codes
Effect
Solution
voltmeter set to resistance verify that pins
3 and 4 on the harness connector
measure between 110 and 130 Ohms.
Check wiring and boom cable for open or
short circuits if resistance check fails.
* Replace PCON if necessary.
Boom Up
Reprogram the machine with latest
and Extend
software. Check
functions will
http://firmware.genielift.com/ for the latest
not operate.
software version.
Controls from
Reprogram the machine with latest
the platform
software. Check
will not
http://firmware.genielift.com/ for the latest
operate.
software version.
Controls from
* Verify DISCON is operating by checking
the ground
that the display on the front is operating
will not
properly.
operate.
* If there is no display, try to power up the
DISCON by setting the keyswitch to
Ground, pull out the ground ESTOP and
press the Ground Function Enable button.
The display should start.
* If there is still no display, check DISCON
power on J10 pins 2 (+) and 1 (-).
* If DISCON operates but fault persists,
check the CAN bus wiring. Disconnect
J10 and with a voltmeter set to resistance
verify that the resistance between pins
3 and 4 on the harness connector are
between 55 and 65 ohms. Check CAN
wiring if resistance check fails.
* Replace DISCON if required.
Boom Up
Reprogram the machine with latest
and Extend
software. Check
functions will
http://firmware.genielift.com/ for the latest
not operate.
software version.
Effect
Solution
Machine will
* Verify TCON is receiving power. Check
not be
for 12 V on J5-2 (+) and J5-1 (-).
functional.
* Verify TCON is receiving ESTOP signals.
With ground ESTOP pulled out and
keyswitch set to Ground, verify 12 V is
reaching TCON J5-9 and J5-12.
* Verify CAN bus is functional. Pull out
connector J5 from the TCON and with a
voltmeter set to resistance verify that pins
3 and 4 on the harness connector
measure between 55 and 65 Ohms.
Check wiring and boom cable for open or
®
• S
-65 XC
Service and Repair Manual
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents