Service and Repair Manual
Control System
Screen or Menu
Sensor Calibrations
Universal Tilt Sensor
Load Sense
Boom Angle Sensor
Boom Length Sensor
Screen or Menu
Auto Threshold
Boom Up / Down Threshold
Calibration
Screen or Menu
Drive Speeds
Forward Threshold
Reverse Threshold
Forward Max
Reverse Max
Forward Out of Stow Max
Reverse Out of Stow Max
Screen or Menu
Drive Ramps
Standard Acceleration
Standard Deceleration
Torque Switching
Deceleration
Screen or Menu
Deutz TD2.9
Threshold
Anti-Stall
Drive Minimum
Range
Hysteresis
26
Item
Calibrate
Calibrate
Calibrate
Calibrate
Item
select OK to Calibrate
Item
124% max, 50% min, 100% = 600 mA (default)
132% max, 50% min, 100% = 540 mA (default)
150% max, 72% min, 100% = 1365 mA (default)
150% max, 72% min, 100% = 1250 mA (default)
150% max, 84% min, 100% = 888 mA (default)
150% max, 81% min, 100% = 888 mA (default)
Item
5000 ms max, 100 ms min, 4000 ms (default)
5000 ms max, 100 ms min, 1000 ms (default)
5000 ms max, 500 ms min, 4000 ms (default)
Item
default = 2375 rpm
default = 50%
default = 125 rpm
default = 100 rpm
®
S
-60 XC
• S
Default
Default
Default
Default
Default
®
-65 XC
September 2018
Part No. 1288652GT