September 2018
ID
Component
ID Name
15 Circuit
27
Primary
12 Circuit
Boom
Retract Valve
15 Circuit
35
Ground
19 Held at
Buttons
36
Jib Up Valve 12 Circuit
15 Circuit
37
Jib Down
12 Circuit
Valve
15 Circuit
41
Turntable
12 Joystick
Rotate
Joystick
15 Joystick
19 Joystick
Part No. 1288652GT
Cause
TCON detected
shorted to
that C7PBE
GND
circuit is shorted
to GND.
TCON detected
shorted to
that C8PBR
V+
circuit is shorted
to 12 V.
TCON detected
shorted to
that C8PBR
GND
circuit is shorted
to GND.
Buttons were held
startup
at system start, or
are shorted on the
ground control
panel.
PCON detected
shorted to
that V43JU circuit
V+
is shorted to 12 V.
PCON detected
shorted to
that V43JU circuit
GND
is shorted to
GND.
PCON detected
shorted to
that V44JD circuit
V+
is shorted to 12 V.
PCON detected
shorted to
that V44JD circuit
GND
is shorted to
GND.
Circuit C165TTR
voltage too
is above 4.5 V.
high.
Circuit C165TTR
voltage too
is below 0.5 V.
low.
Circuit C165TTR
held at
voltage was not
startup.
within the startup
voltage range of
2.5 V +/- 0.2 V.
®
S
-60 XC
Control System Fault Codes
Effect
Solution
* Verify wiring for C7PBE (BK, TCON J4-7)
and check for open or short circuits.
Boom Extend
* With a voltmeter, measure Y25. Proper
and Retract
resistance should be between 5 - 60 ohms.
functions will
Replace Y25 if resistance is outside of
not operate.
those values.
* Verify wiring for C8PBR (BK/WH, TCON
J4-8) and check for open or short circuits.
* Verify resistance between Recovery
Module pins J37-5 and J37-8 is zero
ohms.
The function
* Release the ground control buttons and
cycle power.
associated
with the stuck
* If problem persists, open ground control
button will
box and open the Display Controller
not operate.
access door, being careful to keep water
out. Verify the ribbon cables are properly
seated and dry.
* Re-seat and/or replace ribbon cables if
necessary.
* Replace ground control overlay.
Jip Up
* With a voltmeter, measure Y68. Proper
function will
resistance should be between 5 - 60 ohms.
not operate.
Replace Y68 if resistance is outside of
those values.
* Verify wiring for V43JU (BL, PCON
J12-8) and check for open or short circuits.
Jib Down
* With a voltmeter, measure Y69. Proper
function will
resistance should be between 5 - 60 ohms.
not operate.
Replace Y69 if resistance is outside of
those values.
* Verify wiring for V44JD (BL/BK, PCON
J12-9) and check for open or short circuits.
Turntable
* Leave joystick in neutral position and
Rotate
cycle power.
functions will
* If fault persists, with a voltmeter check
not operate.
that C165TTR (WH/RD, PCON J18-2) is at
2. 5V +/- 0.2 V at startup and does not go
above 4.5 V or below 0.5 V when fully
stroked in each direction.
* Replace joystick if voltage check fails.
®