Operating Instructions and Parts Manual
INSTALLATION (CONT'D)
4. For optimum performance, drain and discharge lines should have a
continuous downward slope. Test operation of pump to make sure
lines have enough downward slope for efficient operation.
5. Avoid overtightening of check valve after cleaning (refer to Maintenance
gudelines).
6. To assure proper performance, the highest point of discharge line
should be higher than 5' off the floor.
7. Clean any debris in the pump reservoir if necessary.
8. Do not handle the pump until you have disconnected it from the power
source.
9. Do not use a pump discharge pipe smaller than the pump
discharge size.
10. After installation, test pump to make sure that system is
working properly.
11. Make sure that installation conforms to all local and national
codes.
12. Local codes may require the use of a condensate neutralizer
when using this pump (refer to Figure 3).

MAINTENANCE

Make certain that the pump is unplugged
before attempting to service or remove any component. This pump
is assembled in the factory using special equipment; therefore only
authorized service dealers or qualified electricians should
attempt to repair the unit. Improper repair can cause an
electrical shock hazard, and void warranty.
Toujours s'assurer que la pompe
est débranchée avant de procéder à un entretien, une réparation ou de
retirer un composant. Cette pompe est assemblée en usine utilisant de
l'équipement spécial, par conséquent seuls des concessionnaires ou
des électriciens qualifiés peuvent essayer de réparer cet appareil. Une
réparation inadéquate peut provoquer un risque de choc électrique et
annulera la garantie.
Disconnect power before servicing. If the power
disconnect is out of sight, lock in the open position and tag it out to
prevent unexpected application of power. Failure to do so could result in
fatal electrical shock.
Débrancher l'alimentation avant de procéder
à l'entretien. Si la source de courant n'est pas visible, verrouiller en
position ouverte et étiqueter pour éviter tout rétablissement inattendu
du courant. Le non-respect de ces instructions pourrait mener à un
choc électrique mortel.
www.waynepumps.com
1. Release all pressure within the system before ser vic ing any
component.
2. Drain all liquids from the system before servicing.
3. Secure the discharge line before starting the pump. An
unsecured discharge line will whip, possibly causing personal
injury and/or property damage.
Insert tubing or pipe through
inlet of pump until this tip
makes contact with the
bottom of reservoir.
Figure 2 - Modification of pipe end to prevent blockage
High efficiency
gas furnace
Condensate
Neutralizer Cartridge
(If Required)
Main Drain from Furnace
Figure 3 - Plumbing pipe from drain to inlet holes on pump
3/8" ID
Tubing
15 Ft.
Max
Hose clamp
(recommended, not included)
Figure 4 - Installation of discharge line
WCP85
Drain Pipe
Diagonally cut 3/8 tube
at approximately 45°.
Main Drain from Coil
Overflow Drain from Coil
When Required
GFCI
Outlet
Overflow
Drain from Furnace
Do not kink or pinch
To Main Drain
Inverted "U"
GFCI
Outlet
5