Operating Instructions and Parts Manual
GENERAL SAFETY INFORMATION (CONT'D)
1. Know the pump application, limitations, and po ten tial hazards.
2. Make certain that the power supply conforms to the
requirements of the unit.
Personal Safety:
a. Wear safety glasses at all times when working
with pumps.
b. Keep work area clean, uncluttered and properly
lighted; replace all unused tools and equipment.
c. Keep visitors a safe distance from the work area.
Risk of electric shock! Never connect either
auxiliary white wire to line voltage. Both white wires are for connection
to an HVAC only. See page 6, figure 5.
Risque de choc électrique! Ne connectez jamais
auxiliaire de fil blanc de la tension de ligne. Les deux fils blancs sont
pour la connexion à un CVC. Voir la page 6, la figure 5.

INSTALLATION

STEP 1: INSTALLATION OF PIPE
A. Insert the discharge pipe or pipe nipple into the 3/8" ID plastic
tube.
Before removing pump from its mounting
position for service, always disconnect electrical power to pump and
control switch. For any work on pump or switch, always unplug the
power cord. Do not just turn off circuit breaker or unscrew fuse.
MISE EN GARDE
Avant de retirer la pompe de sa position
de montage pour réparation, toujours couper le courant à la pompe
et à l'interrupteur. Pour tout travail sur la pompe ou sur l'interrupteur,
toujours débrancher le cordon d'alimentation. Ne pas simplement
éteindre le disjoncteur ou dévisser le fusible.
STEP 2: MOUNTING CONDENSATE UNIT
A. Position the pump below the evaporator drain and/or furnace
drain.
B. The pump can be installed to the wall or side of the appliance
using the two mounting brackets. Refer to Figure 1.
STEP 3: INSTALLATION OF CONDENSATE DRAIN LINES
A. To prevent pipe blockage in the reservoir, modify the end of
pipe or tubing as illustrated in Figure 2.
B. Plumb flexible tube or pipe from the condensate drain, and
from the furnace drain (if applicable), to the inlet holes on the
pump. Refer to Figure 3.
STEP 4: INSTALLATION OF DISCHARGE LINE
NOTE: Use 3/8" I.D. (max.) flexible tubing. A hose clamp is
recommended (not provided).
4
A. Extend discharge pipe from barbed check valve to the highest
point possible. Refer to Figure 4.
B. From this point, direct the discharge line to the location of the
drainage source. Maintain a continuous downward slope.
NOTE: Construct an inverted "U" (see Figure 4) at the highest
point of discharge line if a continuous downward slope is not
possible. Exercise care not to kink or "pinch off" the flow of
condensate liquid.
STEP 5: INSTALLATION OF SAFETY SWITCH (IF
APPLICABLE)
Safety switch is only to be used on Class 2
circuit, 30V AC, 3.2 amps maximum.
MISE EN GARDE
L'interrupteur de sécurité ne doit être
utilisé que sur un circuit de classe 2, 30 volts de c.a., 3,2 ampères
maximum.
Connect power cord to a constant voltage
source. Do not connect to a fan or other device that may run
intermittently.
High efficiency
gas furnace
Figure 1- Mounting location
A. The pump can be wired directly to the appliance thermostat to
shut the appliance down in the event of pump failure. Refer to
Figure 5 for typical wiring diagram.
NOTE: The alarm can be wired in the safety switch at the normally
open ("NO") contact.
TIPS FOR EASY INSTALLATION
1. After reading instructions, check to make sure installation does not
exceed a maximum of 15 feet of vertical lift.
2. Make sure pump is level. No part of the pump base should be more
than 1/8" off of level plane.
3. Use soapy water on unit when performing cleaning maintenance (refer
to Maintenance guidelines).
GFCI Outlet
Mounting
brackets
6 1/2" above floor
www.waynepumps.com