Wayne 370100-001 Operating Instructions Manual

Condensate unit
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Operating Instructions
Description
A condensate unit removes
condensation from air conditioning
and high efficiency furnaces. The
compact design of the unit consists of a
3/8" ID discharge and 6 ft. long power
cord. The unit also contains a safety
switch to automatically shut off pump
in the event of a failure.
Unpacking
Inspect this unit before it is installed.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
This pump is not
designed to handle
salt water, brine, laundry discharge, or
any other application which may contain
caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will void
warranty. Use for clear water application
only.
Safety Guidelines
This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2005 Wayne Water Systems
Condensate Unit
Please read and save these instructions. Read carefully
before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by
observing all safety information. Failure to comply with
instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
indicates important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
1. Know the pump application,
limitations, and po ten tial hazards.
Do not
use to
pump flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not use
in flammable and/or explosive
atmospheres. Use pump only with liquids
compatible with pump component
materials. Failure to follow this warning
can result in personal injury and/or
property damage.
2. Make certain that the power supply
conforms to the requirements of
the unit.
Disconnect power before
servicing. If the power dis -
con nect is out of sight, lock
Specifications
Power supply requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V, 60 Hz, 1 phase
Motor duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intermittent
Liquid temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°F to 125°F
Max. operating position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10" X 5" X 4-3/4"
Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8"ID
Power cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6' 3 conductor with ground
Reservoir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 quart plastic
For parts, product & service information
visit www.waynepumps.com
in the open po si tion and tag it to
prevent unexpected application of
power. Failure to do so could result in
fatal electrical shock!
3. Release all pressure within the
system before ser vic ing any
component.
4. Drain all liquids from the system
before servicing.
5. Secure the discharge line before
starting the pump. An unsecured
discharge line will whip, possibly
causing personal injury and/or
property damage.
6. Check hoses for weak and worn
condition before each use, making
certain that all connections are
secure.
7. Periodically inspect the pump and
system com po nents. Perform
routine maintenance as required
(See Maintenance Section).
8. Provide a means of pressure relief
for pumps whose discharge line can
be shut-off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean,
uncluttered and properly lighted;
o
370100-001 4/05
WCP85
from vertical

Advertisement

Table of Contents
loading

Summary of Contents for Wayne 370100-001

  • Page 1 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2005 Wayne Water Systems Condensate Unit Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
  • Page 2: General Safety Information

    Operating Instructions General Safety Information (Continued) replace all unused tools and equipment. c. Keep visitors a safe distance from the work area. Make workshop child-proof with pad locks, master switch es, and by re mov ing starter keys. 10. When wiring an elec tri cal ly driven pump such as this, fol low all electrical and safety codes, as well as the most recent National Electrical Code (NEC)
  • Page 3 Installation (Continued) furnace drain (if applicable), to the inlet holes on the pump. Refer to Figure 5. STEP 4: INSTALLATION OF DISCHARGE LINE NOTE: Use 3/8” I.D. (max.) flexible tubing.. A hose clamp is recommended (not provided). A. Extend discharge pipe from barbed check valve to the highest point possible.
  • Page 4: Maintenance

    Operating Instructions for efficient operation. 5. Avoid overtightening of check valve after cleaning. (Refer to Maintenance gudelines.) 6. Use constant voltage power source. Do not plug into a device that runs intermittently. 7. Locate model number and date code on pump and take note of them.
  • Page 5: Troubleshooting Chart

    This is normal. No action is necessary. 1. Check valve should be hand-tightened, then tightened an additional 1/2 turn with a 9/16” wrench. 2. Replace with a 1/2” ID x 11/16” OD x 3/32” thick O-ring or contact Wayne Technical Service at 1-800-237-0987. WCP85...
  • Page 6: Limited Warranty

    Limited Warranty For one year from the date of purchase, Wayne (“Wayne”) will repair or re place, at its option, for the original purchaser any part or parts of its Condensate Pump (“Product”) found upon examination by Wayne to be defective in materials or work - man ship.
  • Page 7: Medidas De Seguridad

    RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! © 2005 Wayne Water Systems Unidad de condensación Sírvase leer y conservar estas instrucciones. Léalas con cuidado antes de intentar armar, instalar, operar o efectuar mantenimiento al producto descrito.
  • Page 8: Instalación

    Manual de Instrucciones de Operación Informaciones Generales de Seguridad (Continuación) 9. Seguridad personal: a. Use gafas de seguridad en todo momento al trabajar con bombas. b. Mantenga el área de trabajo limpia, ordenada e iluminada, ordene las herramientas y equipos sin utilizar. c.
  • Page 9 PASO 2: MONTAJE DE LA UNIDAD DE CONDENSACIÓN A. Coloque la bomba debajo del drenaje del evaporador y/o del drenaje del horno. B. La bomba se puede instalar en la pared o en un costado del aparato usando los dos soportes de montaje. Consulte la Figura 3.
  • Page 10: Mantenimiento

    Manual de Instrucciones de Operación aparato en caso de que la bomba falle. Consulte la Figura 7 para ver un diagrama de cableado típico. NOTA: La alarma se puede conectar en el interruptor de seguridad al contacto normalmente abierto (“NO”). CONSEJOS PARA LA FÁCIL INSTALACIÓN 1.
  • Page 11: Guía De Diagnóstico De Averías

    Si la lista anterior no resuelve el problema, póngase en contacto con el Servicio Técnico de Wayne al 1- 800-237-0987.
  • Page 12: Garantía Limitada

    Garantía Limitada Durante un año a partir de la fecha de compra, Wayne ("Wayne") reparará o reemplazará para el comprador original, según lo que decida, cualquier pieza o piezas de su Juego para estanque, Unidad de condensación ("Producto") que después de un examen Wayne encuentre que tenían defectos en su material o mano de obra.

This manual is also suitable for:

Wcp85