3 Communications Data for CompoWay/F
Variable
Address
type
C1 (81)
0016
C1 (81)
0017
C1 (81)
0019
C1 (81)
001A
C1 (81)
001B
C1 (81)
001C
C1 (81)
001D
C1 (81)
001E
C1 (81)
001F
C1 (81)
0020
C1 (81)
0021
C1 (81)
0022
C1 (81)
0023
3 - 4
Parameter name
Integral Time
Standard, heating/cooling, or close
position-proportional control:
H'00000000 to H'0000270F
(0 to 9999: Integral/derivative time unit is 1 s.)
(0.0 to 999.9: Integral/derivative time unit is 0.1 s.)
Floating position-proportional control:
H'00000001 to H'0000270F
(1 to 9999: Integral/derivative time unit is 1 s.)
(0.1 to 999.9: Integral/derivative time unit is 0.1 s.)
Derivative Time
H'00000000 to H'0000270F
(0 to 9999: Integral/derivative time unit is 1 s.)
(0.0 to 999.9: Integral/derivative time unit is 0.1 s.)
Dead Band
H'FFFFF831 to H'0000270F
(−199.9 to 999.9 for temperature input)
(−19.99 to 99.99 for analog input)
Manual Reset
H'00000000 to H'000003E8 (0.0 to 100.0)
Value
Hysteresis
H'00000001 to H'0000270F
(Heating)
(0.1 to 999.9 for temperature input)
(0.01 to 99.99 for analog input)
Hysteresis
H'00000001 to H'0000270F
(Cooling)
(0.1 to 999.9 for temperature input)
(0.01 to 99.99 for analog input)
Heater Burnout
H'00000000 to H'000001F4 (0.0 to 50.0)
Detection 2
HS Alarm 1
H'00000000 to H'000001F4 (0.0 to 50.0)
HS Alarm 2
H'00000000 to H'000001F4 (0.0 to 50.0)
Soak Time
H'00000001 to H'0000270F (1 to 9999)
Wait Band
H'00000000 (0): OFF
H'00000001 to H'0000270F
(0.1 to 999.9 for temperature input)
(0.01 to 99.99 for analog input)
MV at Stop
Standard Models
Standard control:
MV at PV Error
H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Heating and cooling control:
H'FFFFFBE6 to H'0000041A (−105.0 to 105.0)
Position-proportional Models
Close position-proportional control with the Direct
Setting of Position Proportional MV parameter set to
ON:
H'FFFFFFCE to H'0000041A (−5.0 to 105.0)
Floating position-proportional control or the Direct
Setting of Position Proportional MV parameter set to
OFF:
H'FFFFFFFF to H'00000001 (−1 to 1)
Setting (monitor) value